Three Phase UPS : CN-TB33 SERIES (10-600KVA)
Features:
Part No. | Description |
77-1015- U |
CN-TB31 Series, Online transformer based double conversion UPS (three Phase In – single phase out), 10kVA/8kW, 0.8pf, 192Vdc, with IGBT inverter, output isolation transformer, 2A charger with 32 x 12V, 7Ah batteries |
77-1016-U |
CN-TB31 Series, Online transformer based double conversion UPS (three Phase In – single phase out), 10kVA/8kW, 0.8pf, 192Vdc, with IGBT inverter, output isolation transformer, 4A charger without batteries |
77-1017-U |
CN-TB31 Series, Online transformer based double conversion UPS (three Phase In – single phase out), 15kVA/12kW, 0.8pf, 192Vdc, with IGBT inverter, output isolation transformer, 2A charger with 32 x 12V, 7Ah batteries |
77-1018-U |
CN-TB31 Series, Online transformer based double conversion UPS (three Phase In – single phase out), 15kVA/12kW, 0.8pf, 192Vdc, with IGBT inverter, output isolation transformer, 4A charger without batteries |
77-1019-U |
CN-TB31 Series, Online transformer based double conversion UPS (three Phase In – single phase out), 20kVA/16kW, 0.8pf, 348Vdc, with IGBT inverter, output isolation transformer, 10~20A selectable charger without batteries |
77-1020-U |
CN-TB31 Series, Online transformer based double conversion UPS (three Phase In – single phase out), 30kVA/24kW, 0.8pf, 348Vdc, with IGBT inverter, output isolation transformer, 10~20A selectable charger without batteries |
77-1021-U |
CN-TB31 Series, Online transformer based double conversion UPS (three Phase In – single phase out), 40kVA/32kW, 0.8pf, 348Vdc, with IGBT inverter, output isolation transformer, 10~20A selectable charger without batteries |
77-1022-U | CN-TB31 Series, Online transformer based double conversion UPS (three Phase In – single phase out), 50kVA/40kW, 0.8pf, 348Vdc, with IGBT inverter, output isolation transformer, 10~20A selectable charger without batteries |
Part No. | Description |
77-1001- U |
CN-TB11 Series, Online transformer based double conversion UPS (single Phase In – single phase out), 1kVA/0.8kW, 0.8pf, 48Vdc, with IGBT inverter, output isolation transformer, 1A charger with 4 x 12V, 7Ah batteries |
77-1002-U |
CN-TB11 Series, Online transformer based double conversion UPS (single Phase In – single phase out), 1kVA/0.8kW, 0.8pf, 48Vdc, with IGBT inverter, output isolation transformer, 4.5A charger without batteries |
77-1003-U |
CN-TB11 Series, Online transformer based double conversion UPS (single Phase In – single phase out), 2kVA/1.6kW, 0.8pf, 48Vdc, with IGBT inverter, output isolation transformer, 1A charger with 8 x 12V, 7Ah batteries |
77-1004-U |
CN-TB11 Series, Online transformer based double conversion UPS (single Phase In – single phase out), 2kVA/1.6kW, 0.8pf, 48Vdc, with IGBT inverter, output isolation transformer, 4.5A charger without batteries |
77-1005-U |
CN-TB11 Series, Online transformer based double conversion UPS (single Phase In – single phase out), 3kVA/2.4kW, 0.8pf, 96Vdc, with IGBT inverter, output isolation transformer, 1A charger with 8 x 12V, 7Ah batteries |
77-1006-U |
CN-TB11 Series, Online transformer based double conversion UPS (single Phase In – single phase out), 3kVA/2.4kW, 0.8pf, 192Vdc, with IGBT inverter, output isolation transformer, 4.5A charger without batteries |
77-1007-U |
CN-TB11 Series, Online transformer based double conversion UPS (single Phase In – single phase out), 5kVA/4kW, 0.8pf, 192Vdc, with IGBT inverter, output isolation transformer, 1A charger with 16 x 12V, 7Ah batteries |
77-1008-U | CN-TB11 Series, Online transformer based double conversion UPS (single Phase In – single phase out), 5kVA/4kW, 0.8pf, 192Vdc, with IGBT inverter, output isolation transformer, 8A charger without batteries |
77-1009-U |
CN-TB11 Series, Online transformer based double conversion UPS (single Phase In – single phase out), 6kVA/4.8kW, 0.8pf, 192Vdc, with IGBT inverter, output isolation transformer, 1A charger with 16 x 12V, 7Ah batteries |
77-1010-U |
CN-TB11 Series, Online transformer based double conversion UPS (single Phase In – single phase out), 6kVA/4.8kW, 0.8pf, 192Vdc, with IGBT inverter, output isolation transformer, 8A charger without batteries |
77-1011-U |
CN-TB11 Series, Online transformer based double conversion UPS (single Phase In – single phase out), 10kVA/8kW, 0.8pf, 192Vdc, with IGBT inverter, output isolation transformer, 2A charger with 32 x 12V, 7Ah batteries |
77-1012-U |
CN-TB11 Series, Online transformer based double conversion UPS (single Phase In – single phase out), 10kVA/8kW, 0.8pf, 192Vdc, with IGBT inverter, output isolation transformer, 6A charger without batteries |
77-1013-U |
CN-TB11 Series, Online transformer based double conversion UPS (single Phase In – single phase out), 15kVA/12kW, 0.8pf, 192Vdc, with IGBT inverter, output isolation transformer, 3A charger with 48 x 12V, 7Ah batteries |
77-1014-U |
CN-TB11 Series, Online transformer based double conversion UPS (single Phase In – single phase out), 15kVA/12kW, 0.8pf, 192Vdc, with IGBT inverter, output isolation transformer, 4.5A charger without batteries |